GTS 114 Gas Turbine Intake Filter Test System
High-flow test system for gas-turbine and rotary-machinery intake filters, combining particle, salt and water-endurance testing under adjustable temperature and humidity conditions.
Model Overview
| Model | System purpose | Standards / method | Core fit |
|---|---|---|---|
| GTS 114 | High-flow conditioned-air test system for gas-turbine and rotary-machinery intake filters | ISO 29461-1, ISO 29461-2, ISO/AWI 29461-4, ISO 16890-2/-3/-4, ASHRAE 52.2 | Particle efficiency, salt removal, dust holding and water-endurance testing |
Key Features
ISO 29461 workflows
Configured for gas-turbine intake-filter testing, including water endurance and salt-removal evaluation.
Controlled air conditions
Circulation mode enables adjustment and stabilisation of test-air temperature and humidity.
Multiple aerosol challenges
Introduces NaCl, KCl, DEHS and standard test dusts into an optimised flow profile.
Water and vapour loading
Automated feeding of water droplets and supersaturated vapour supports endurance procedures.
Flexible filter formats
Accommodates cassettes, pocket filters, cartridges and flat media.
High automation level
Operator-guided, mostly automated sequences support repeatable data and documentation.
Technical Specifications
| Parameter | Unit | Value / Description |
|---|---|---|
| TEST RANGE | ||
| Test-flow range | m³/h | 800–11,000 |
| Maximum specimen differential pressure | Pa | 2000 |
| Panel-filter size | mm | 610 × 610 for pocket and cassette filters |
| Cartridge capacity | mm | Diameter up to 400; length up to 1500 |
| Test aerosols | — | DEHS, KCl, ASHRAE dust, ISO 12103 A2 and A4 |
| CONDITIONING AND UTILITIES | ||
| Air circulation | % | 0–100 |
| Compressed-air supply | bar | Minimum 5; approximately 17 m³/h |
| Water supply | bar | Minimum 3 |
| Power supply | — | 3 × 400 V AC; 125 A; 50 Hz |
| Dimensions (W × H × D) | m | 4.6 × 1.7 × 14.0 |
Published values support initial model selection. Confirm final configuration, utilities, accessories and calibration scope during technical review.
Applications
Gas-turbine intake filters
Performance testing of complete intake-filter systems for rotary machinery.
ISO 29461 testing
Particle, salt-removal and water-endurance workflows aligned with the ISO 29461 series.
Fractional and gravimetric efficiency
Measurement of size-resolved and mass-based filter separation performance.
Dust-holding capacity
Evaluation of pressure-drop development and dust-holding behaviour.
Humidity and water endurance
Testing under controlled humidity, water-droplet and vapour exposure.
General-air filters
Optional testing of ventilation filters according to ISO 16890 and ASHRAE 52.2.